Direct Central Passage
The two moving leaves open away from the center, creating a clearly defined passage through the middle of the entrance. The required passage width must be reviewed together with the complete structural opening.

Center-Opening Sliding Entrances
Two moving door leaves open away from the center to create a direct central passage. Plan the entrance around the required clear opening, usable travel space on both sides, door-leaf construction, sensing and control requirements.
Product Definition
A bi-parting automatic sliding door uses two moving leaves that meet at the center when closed and travel in opposite directions when opening. The movement creates a central pedestrian route and a balanced entrance appearance.
The complete entrance may include fixed side panels, glazed or framed moving leaves, an overhead operator, activation sensing, presence-safety detection, operating controls, locking interfaces and project-defined access-control connections.
Consider a bi-parting layout when the project requires a central opening and has usable door-travel space on both sides. The final arrangement still depends on the structural opening, target clear passage, door-leaf dimensions and weight, façade conditions and system interfaces.
If the required passage cannot be achieved with the available side space, another sliding-door product direction, such as a telescopic arrangement, should be reviewed.

Decision Benefits
The two moving leaves open away from the center, creating a clearly defined passage through the middle of the entrance. The required passage width must be reviewed together with the complete structural opening.
Center-opening movement supports a symmetrical façade composition and keeps the pedestrian route aligned with the visual center of the entrance.
A central passage can support users approaching from both directions when the opening time, sensing zones and surrounding circulation are planned around the actual traffic pattern.
Door leaves, frames, glass, operator system, sensors, controls, locking and supply scope can be reviewed according to the project. Final options depend on verified dimensions, loads and interface requirements.
Selection Conditions
Confirm the full opening width and height, and identify whether the dimensions are structural, finished, or preliminary.
Confirm the usable passage required when the door is fully open. This affects the moving-leaf and fixed-panel arrangement.
Confirm the usable travel area on both sides. Columns, walls, glazing lines, façade details and other obstructions may affect the layout.
Confirm the proposed leaf dimensions, frame system, glass, hardware and estimated or verified leaf weight.
Describe approach directions, peak traffic, wheeled access and the required activation and presence-safety sensing zones.
Confirm access-control, locking and operating-mode requirements alongside the complete-door scope and work by others.
Layout Comparison
| Selection point | Bi-Parting Sliding Door | Telescopic Sliding Door |
|---|---|---|
| Opening movement | Two moving leaves travel away from the center | Multiple leaves slide and stack in sequence |
| Space condition | Requires usable door-travel space on both sides | Consider when side travel space is more restricted |
| Passage position | Creates a central passage | Passage position depends on the selected layout |
| Main review points | Symmetry, central route and travel space on both sides | Leaf stacking, pocket space and opening utilization |
This comparison is a planning guide rather than a fixed engineering rule. Final selection requires the opening dimensions, leaf construction and operator configuration.
Explore Telescopic Sliding DoorsSystem Coordination
The final supply scope should be confirmed project by project. A complete bi-parting entrance may include the following components.
Houses the drive, controller and supporting mechanisms above the entrance.
Transfers controlled movement to the two door leaves through the selected operator configuration.
Coordinates opening, closing, speed, hold-open time, operating modes and connected signals.
Support and guide the moving leaves; selection depends on the door construction and verified load.
Detects an approaching user or receives an approved activation signal.
Monitors defined areas around the threshold and door path according to the selected sensing arrangement.
Connects compatible access-control, operating-mode and locking functions where required.
Complete the entrance according to the approved layout, material, finish and glazing specification.
Technical Reference
| Parameter | Typical configuration |
|---|---|
| Clear Opening Width | 700–3,000 mm, customizable |
| Opening Height | 2,000–3,000 mm, customizable |
| Maximum Leaf Weight | 100–200 kg per leaf, subject to operator and configuration |
| Opening Speed | 100–700 mm/s, adjustable |
| Closing Speed | 100–600 mm/s, adjustable |
| Hold-Open Time | 0–60 seconds, adjustable |
| Motor | Brushless DC motor |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Activation | Microwave sensor, push button, or access control |
| Safety Protection | Presence detection and obstacle response |
| Operating Modes | Automatic, Open, Closed, Partial Open, and One-Way |
| Frame Options | Aluminum, stainless steel, or frameless glass |
| Glass Options | Tempered, laminated, or insulated glass |
| Installation | Concealed or surface-mounted |
| Access Control | Card reader, keypad, face recognition, or building system |
| Customization | Size, finish, glass, sensors, and control functions |
These specifications represent common configuration ranges for automatic sliding doors. Final dimensions, door-leaf weight, operating speed, sensors and control functions must be confirmed according to the entrance size, selected operator, door construction, traffic and project requirements.
Applications

Supports a clear central arrival route for guests, luggage and daily lobby traffic when the entrance dimensions and sensing zones are properly planned.
View Hotel Entrance Solutions
Fits symmetrical main entrances that must coordinate employee, visitor and project-defined access-control requirements.
View Office Entrance Solutions
Can support continuous two-way customer movement when opening size, door timing and sensing are configured for the actual traffic pattern.
View Shopping Center Solutions
Suitable for public lobby or general circulation entrances where wheeled access and sensing coverage are considered. This is not presented as an airtight operating-room door.
Explore Hospital Automatic Sliding Door Solutions
Creates a centered storefront passage while retaining a balanced glazed façade.
View Retail Entrance Solutions
Can be configured for regular pedestrian flows where the structure, opening and interface requirements have been verified.
View Public Entrance SolutionsQuotation Preparation
A product name alone is not enough to configure the entrance. Share the following information so the layout, supply scope and remaining decisions can be reviewed.
Project Workflow
Review dimensions, photographs, drawings, traffic and requested scope.
Check the target central passage, moving-leaf arrangement and usable travel space on both sides.
Select the provisional operator, components, sensing, controls and supply scope for quotation.
Confirm the layout, supporting structure, power, signals, access-control and installation responsibilities.
Manufacture or prepare the approved supply scope, complete the required checks and package it for shipment.
Arrange shipment according to the agreed terms and provide applicable documents and remote coordination.
Project Cases

A bi-parting sliding glass entrance was configured to support daily guest arrivals and luggage movement within a compact hotel lobby.
View Project Details
A bi-parting entrance was supplied for concentrated employee and visitor traffic, with a wide passage, sensing and project-defined access-control interfaces.
View Project Details
A commercial bi-parting entrance was configured for continuous two-way customer movement, including families, strollers, wheelchairs and shopping carts.
View Project DetailsFrequently Asked Questions
A bi-parting automatic sliding door has two moving leaves that meet at the center when closed and travel in opposite directions when opening, creating a central passage.
It depends on the required clear passage, moving-leaf dimensions, fixed panels, frame system and operator arrangement. Provide the full opening width and the usable space on both sides for layout review.
The review uses the structural opening, required clear passage, leaf dimensions, glass, frame, hardware and verified or calculated leaf weight. Final values must match the selected operator configuration.
Sensor selection depends on the approach directions, pedestrian flow, threshold and monitored areas. Activation and presence-safety functions may be combined or provided by separate devices according to the configuration.
Compatible card readers, keypads, face-recognition devices, reception controls or building systems can be reviewed. Signal type, controller logic, locking and device compatibility must be confirmed before supply.
Our main focus is complete door supply. Operator systems, components and accessories are generally supplied to existing customers as replacement, spare or repair parts. Large-volume standalone requirements, such as hundreds or thousands of sets, can be discussed separately. The quotation lists inclusions and exclusions.
Price depends on the opening, door-leaf construction and weight, operator, sensors, controls, access and locking interfaces, finish, quantity, supply scope, packaging and destination.
Confirm the entrance dimensions, clear passage, side travel space, moving leaves, fixed panels, supporting structure, power, sensors, access control, locking and the responsibilities of each party.
Continue Your Research
Project Inquiry
Share the available opening, required central passage, usable side space, door-leaf information, traffic, sensing, access requirements, quantity, destination and requested supply scope.
Drawings, opening details and site photographs can help identify the remaining decisions.