Telescopic automatic sliding door with multiple framed moving panels at a commercial entrance

Space-Efficient Sliding Entrances

Telescopic Automatic Sliding Door

Multiple moving door leaves slide and stack in sequence to help projects obtain a larger usable clear opening where side travel space is limited. Final selection depends on the structural opening, required passage, stacking area, door-leaf construction and operator configuration.

  • Multi-panel sequential movement
  • Greater clear-opening utilization
  • Layout planning for limited side space

Product Definition

What Is a Telescopic Automatic Sliding Door?

A telescopic automatic sliding door uses multiple moving leaves that travel and stack in sequence. This arrangement can make more effective use of the available side area when a project requires a larger clear passage than a standard sliding layout may provide.

The complete entrance may include moving leaves, fixed panels, an overhead operator, synchronized drive components, activation sensing, presence-safety detection, operating controls, locking interfaces and project-defined access-control connections.

Open telescopic automatic sliding door with multiple panels stacked to both sides and arrows indicating movement

View Full-Size Diagram

Selection Conditions

Confirm Six Conditions Before Choosing a Telescopic Layout

01

Structural Opening

Confirm the full opening width and height and identify whether the values are structural, finished, or preliminary dimensions.

02

Required Clear Passage

Confirm the usable passage required when the door is fully open.

03

Available Panel-Stacking Area

Confirm the usable stacking space on the selected side or sides and identify walls, columns, glazing lines, façade details, or other obstructions.

04

Door-Leaf Construction and Weight

Confirm the proposed number of leaves, dimensions, frame system, glass, hardware, and estimated or verified moving weight.

05

Traffic and Safety Sensing

Describe approach directions, peak traffic, wheeled access, and the required activation and presence-safety sensing zones.

06

Access Control and Supply Scope

Confirm access-control, locking, operating-mode requirements, and whether the request covers a complete entrance or an operator and control package.

Layout Comparison

Telescopic, Standard Sliding or Bi-Parting?

Selection PointTelescopic Sliding DoorStandard Sliding DoorBi-Parting Sliding Door
Opening movementMultiple leaves move and stack in sequenceMoving leaves travel into the available side area without sequential stackingTwo moving leaves travel away from the center
Side-space conditionConsider when side travel is constrained but panel-stacking space is availableSuitable when the selected leaf arrangement has sufficient travel areaRequires usable door-travel space on both sides
Clear-opening planningIntended to make greater use of the available structural openingClear passage depends on the leaf arrangement and available travel areaCreates a central passage based on the opening and side travel
Passage positionDepends on the selected one-sided or two-sided telescopic layoutDepends on the selected sliding directionNormally positioned at the center
Main selection reasonBalance limited side space with a larger required passageUse a simpler sliding arrangement where travel space is sufficientCreate a centered, symmetrical entrance
Key review inputsStructural opening, target passage, stacking area, leaf arrangement, and operatorStructural opening, sliding direction, leaf size, and travel spaceStructural opening, central passage, and travel space on both sides

This comparison is a project-planning guide rather than a fixed engineering rule. Final selection requires verified opening dimensions, door-leaf construction, panel movement, operator configuration and interface requirements.

Decision Benefits

Why Consider a Telescopic Sliding Layout?

More Effective Use of Limited Side Space

Multiple moving leaves stack in sequence, providing another layout direction when the available side travel area is constrained.

Larger Usable Passage Planning

A telescopic layout can be evaluated when a standard sliding arrangement does not provide the required clear passage within the available opening conditions.

Flexible Panel Arrangement

The number of leaves, movement direction, fixed panels, and stacking position can be reviewed against verified opening and system information.

Coordinated Entrance System

Door movement, operator, sensing, safety monitoring, locking, access-control interfaces, and supply scope are reviewed as one entrance system.

System Coordination

Typical Telescopic Entrance System Components

01

Telescopic Door Operator

Houses the drive, controller, and mechanisms required for the selected multi-panel movement.

02

Motor and Drive Components

Move the door leaves according to the selected telescopic arrangement.

03

Controller

Coordinates opening, closing, speed, hold-open time, operating modes, and connected control signals.

04

Track and Hangers

Support and guide the moving leaves; selection depends on verified door construction and load.

05

Moving Leaves, Fixed Panels and Frames

Form the entrance according to the approved layout, glazing, frame, finish, and stacking arrangement.

06

Activation Sensing

Detects approaching users or receives an approved activation signal.

07

Presence-Safety Detection

Monitors defined areas around the threshold, passage, and moving-panel path according to the selected sensing arrangement.

08

Access and Locking Interface

Connects compatible access-control, operating-mode, and locking functions where required.

Technical Reference

Technical Parameters

ParameterStandard Specification
Clear Opening Width700–3,000 mm, customizable
Opening Height2,000–3,000 mm, customizable
Maximum Leaf Weight100–200 kg per leaf, subject to operator and configuration
Opening Speed100–700 mm/s, adjustable
Closing Speed100–600 mm/s, adjustable
Hold-Open Time0–60 seconds, adjustable
MotorBrushless DC motor
Power SupplyAC 110–240 V, 50/60 Hz
ActivationMicrowave sensor, push button, or access control
Safety ProtectionPresence detection and obstacle response
Operating ModesAutomatic, Open, Closed, Partial Open, and One-Way
Frame OptionsAluminum, stainless steel, or frameless glass
Glass OptionsTempered, laminated, or insulated glass
InstallationConcealed or surface-mounted
Access ControlCard reader, keypad, face recognition, or building system
CustomizationSize, finish, glass, sensors, and control functions

These specifications represent common configuration ranges for automatic sliding doors. Final dimensions, door-leaf weight, operating speed, sensors, control functions and telescopic panel arrangement must be confirmed according to the entrance, selected operator and project requirements.

Applications

Where Can a Telescopic Sliding Door Be Evaluated?

Automatic sliding glass door at a retail storefront entrance

Retail Storefronts

Evaluate a telescopic layout when the storefront opening and limited side area must be balanced with the required customer passage.

View Retail Storefront Solutions
Automatic sliding glass entrance opening into a hotel lobby

Hotel Entrances

Review the layout when guests, luggage, and daily lobby traffic require a clear passage within constrained entrance conditions.

View Hotel Entrance Solutions
Automatic sliding glass door at an office building entrance

Office Buildings

Coordinate the entrance layout with visitor circulation, employee access, façade conditions, and project-defined access control.

View Office Entrance Solutions
Automatic sliding glass entrance in a shopping center

Shopping Centers

Review the target passage for two-way traffic, carts, strollers, and wheelchairs against the available structural and stacking space.

View Shopping Center Solutions
Automatic sliding glass door at a hospital public corridor

Hospital Public Entrances

Evaluate the layout for public lobbies and general circulation where wheeled access and safety sensing are considered. Do not present it as an airtight operating-room door.

View Hospital Entrance Solutions
Automatic sliding glass entrance at a public transport building

Public and Transport Entrances

Review the product where a larger passage and regular pedestrian flow must be coordinated with limited available side travel.

View Public Entrance Solutions

Quotation Preparation

Information Needed for a Useful Telescopic Door Quotation

A product name alone is not enough to configure the entrance. Share the following information so the panel layout, system scope and remaining decisions can be reviewed.

Project Location
Share the country and project location for quotation review.
Structural Opening Width and Height
Provide the full structural opening dimensions and identify whether they are finished or preliminary.
Required Clear Passage
State the usable passage required when the selected entrance is fully open.
Available Panel-Stacking Space
Confirm the usable stacking space on the selected side or sides, including possible obstructions.
Proposed Number and Movement of Door Leaves
Describe the proposed panel arrangement and the preferred movement direction where known.
Door Frame, Glass, Hardware, and Estimated Leaf Weight
Provide the proposed leaf construction and estimated or verified moving weight.
Quantity and Expected Pedestrian Traffic
State the required quantity, approach directions, expected traffic, and wheeled access needs.
Activation and Presence-Safety Requirements
Describe the required activation method and presence-safety sensing around the passage.
Access Control, Locking, and Operating Modes
Identify required access devices, locking functions, control signals, and operating modes.
Complete Entrance and Supply Scope
Complete-door requirements, or the original order reference for spares; quantity and items supplied by others
Architectural Drawings and Site Photographs
Attach drawings, opening details, and site photographs when available for layout review.

Project Workflow

From Opening Information to Delivery

  1. 01

    Project Information Review

    Review dimensions, photographs, drawings, traffic, interfaces, and requested scope.

  2. 02

    Telescopic Layout Evaluation

    Check the target passage, panel arrangement, movement direction, and available stacking space.

  3. 03

    System Configuration and Quotation

    Select the provisional operator, components, sensing, controls, and supply scope for quotation.

  4. 04

    Drawing and Interface Confirmation

    Confirm the layout, supporting structure, power, signals, access-control interfaces, and responsibilities.

  5. 05

    Production, Inspection and Packaging

    Manufacture or prepare the approved supply scope, complete the required checks, and package it for shipment.

  6. 06

    Shipment and Remote Support

    Arrange shipment according to the agreed terms and provide applicable documents, online installation guidance, and remote troubleshooting support.

2011
Founded
20,000+ m²
Factory Area
90+
Countries and Regions Served
7,600+
Enterprise Customers
1,000,000
Operational Cycles for Key Door-System Testing
OEM/ODM
Solution Provider
Learn About SEPPES

Frequently Asked Questions

Frequently Asked Questions

What is a telescopic automatic sliding door?

A telescopic automatic sliding door uses multiple moving leaves that travel and stack in sequence. The layout is evaluated when the project needs to balance available side travel with the required clear passage.

How is a telescopic door different from a standard sliding door?

A standard sliding layout moves its leaves into the available side area without sequential panel stacking. A telescopic layout uses multiple leaves that stack in sequence, so the appropriate choice depends on the opening, target passage, travel area, leaf construction, and operator.

What is the difference between telescopic and bi-parting sliding doors?

A bi-parting door normally creates a central passage with moving leaves travelling toward opposite sides. A telescopic layout stacks multiple leaves on one or both sides according to the selected arrangement.

How much panel-stacking space is required?

The required area depends on the structural opening, target clear passage, number and size of moving leaves, frame and glass construction, hardware, and operator arrangement. Provide the complete opening and available side-area dimensions for layout review.

How are the number of moving leaves and clear opening confirmed?

They are confirmed from the structural opening, required passage, available stacking area, door-leaf dimensions and weight, fixed-panel arrangement, and selected operator configuration.

Can a telescopic door connect to an access-control system?

Compatible card readers, keypads, face-recognition devices, reception controls, or building systems can be reviewed. Signal type, controller logic, locking, and device compatibility must be confirmed before supply.

Can SEPPES supply a complete entrance or only the operator system?

Our main focus is complete door supply. Operator systems, components and accessories are generally supplied to existing customers as replacement, spare or repair parts. Large-volume standalone requirements, such as hundreds or thousands of sets, can be discussed separately. The quotation states inclusions and exclusions.

What affects the price of a telescopic automatic sliding door?

Price depends on the opening, panel arrangement, door-leaf construction and weight, operator, sensors, controls, access and locking interfaces, finish, quantity, supply scope, packaging, and destination.

Continue Your Research

Related Products and Planning Resources

Automatic Sliding Doors

Explore the sliding-door family and compare product directions against the entrance opening and available travel space.

Explore All Automatic Sliding Doors

Automatic Sliding Glass Door

Review a glazed sliding-door entrance with system components, technical parameters, and quotation preparation guidance.

View Automatic Sliding Glass Door

Bi-Parting Automatic Sliding Door

Compare a centered, symmetrical sliding entrance when usable travel space exists on both sides.

Compare Bi-Parting Sliding Doors

Automatic Door Systems

Review operator, controller, sensor, track, hanger, and configuration considerations for automatic entrances.

Explore Automatic Door Systems

Project Inquiry

Send Your Telescopic Entrance Requirements

Share the structural opening, required clear passage, available panel-stacking space, door-leaf information, traffic, sensing, access requirements, quantity, destination and requested supply scope.

Drawings, opening details and site photographs can help identify the remaining layout and system decisions.

We use your details only to respond to this inquiry. Read our Privacy Policy.