Project Overview
Entrance Requirement
The building required a formal and controlled entrance that could manage different categories of users without creating an unwelcoming public environment.
The project requirements included:
- Organized movement of employees, visitors and service personnel
- Integration with employee card readers and visitor management procedures
- Remote release and operating control from the security desk
- Reduced risk of unauthorized entry or tailgating
- Multiple modes for public hours, controlled access and full locking
- Safe movement for first-time visitors and slower-moving users
- Coordination with the building’s security and surveillance systems
- Fire alarm release and emergency operating functions
- Reduced drafts and outdoor air exchange in the main lobby
- An accessible side entrance for wheelchairs and oversized items
- Architectural finishes appropriate for a civic building
Verified Project Evidence
Key Project Requirements
Render the approved requirement list from the `Entrance Requirement` source content in a separate visual group. Do not invent additional challenges.
Verified Project Evidence
Supplied Automatic Door System
A customized access-controlled automatic revolving door system was supplied for the government building entrance.
The supplied system included:
The control logic was programmed to allow public automatic operation during designated hours and restricted access through authorized credentials or security release at other times.
- Custom canopy and revolving drum enclosure
- Commercial automatic drive and transmission assembly
- Intelligent programmable controller
- Central shaft and glazed revolving wings
- Curved laminated safety glass panels
- Directional activation and presence sensors
- Multi-zone anti-pinch and anti-collision detection
- Employee card reader interface
- Visitor management and reception release interface
- Security desk control panel
- Configurable anti-tailgating logic
- Normal automatic, controlled-entry, exit-only and locked modes
- Emergency stop and project-defined controlled release interfaces
- Fire alarm and building management system connections
- CCTV and security system interface provisions
- Night locking system
- Accessible automatic side entrance
- Complete installation and control hardware
Verified Project Evidence
Project Outcome
The completed entrance gives the building’s security team greater control over the main access point while maintaining a clear and professional arrival experience for approved visitors.
Employees can use the existing access system, and reception personnel can manage visitor entry without manually operating the door. The revolving enclosure also limits direct drafts and air exchange, while the integrated safety and emergency controls support the operational requirements of a public administration facility.
---